SPECIFICATIONS
Usage: outdoor
Display Type: DIGITAL
Brand Name: OOTDTY
Certification: none
Origin: Mainland China
Power Type: Charger
Model Number: Temperature Gauge
Theory: Temperature Sensor
Hign-concerned Chemical: None
Max Measuring Temperature: 120°C & Above
Display Size: 1.9 Inches & Under
Style: Standing Station
Choice: yes
semi_Choice: yes
DIY Multifunction High-precision clock inside and outside Car temperature Battery voltage Monitor Panel Meter for DC 12v
Description:
Multi-functional electronic clock module, set for time, inside and outside temperature, voltage as one. You can display a single item, or you can cycle through the items alternately and customize the item to be displayed. for Time chip using for Epson's RX8025T chip, this chip is a temperature compensated clock chip, for time accurate. Standard 0.3 for m +1.5 for m module with two waterproof probes, temperature range -35 ~ 120 degrees. With brightness adjustment, 3 brightness adjustable. And automatic brightness function, can be dark at night, brighten during the day.
Specifications:
1, working voltage: for DC 5.0 ~ 28V
2, frame size: 22 * 58 mm
3, Installation hole size: 19.5 * 56 mm
4, Voltage display range: 5.0 ~ 28V
5, temperature display range: -35 ~ 120 ℃ (Two temperature sensors ,0.3 meters +1.5 meters)
6, power lead length: 28CM
How to use:
UP the key:
Under normal display, pressing this for key will switch between the six display states of 【Time】 → 【Date】 → 【Temperature 1】 → 【Temperature 2】 → 【Voltage】 → 【Alternating Cycle Display】. (Note: The display items and switching interval for time in alternate cycle display mode can be customized by "dd" and "dF" parameters respectively. See the following table
Under the key:
Under normal display status, press this for key to enter the setting of for time date year parameter. Press the for key, "points" began to flash, press the button to adjust the value. After adjusting, press the for key again, "hour" starts flashing, press the for key to adjust the value. And then press the for key to enter the date adjustment [Note that the middle of the colon is not lit], "day" began to flash, press the for key after the tune "month" began to flash, tune and then press the for key "year" start Flashes, press the for key to adjust the parameters into the extended set, see the following "code significance and role of the table"
The significance of the code, please refer to the following
1.0.0u
Voltage measurement error correction, a positive number increases, a negative number decreases. For example, the actual supply voltage is 12.0V, but the table shows 11.9V, it is adjusted to 0.1u.
2.Ac
Temperature ① error calibration parameters. Positive number increases, negative number decreases, the unit is degree, the adjustment range is -5 ~ 5. For example, if you think the displayed temperature is 1 degree higher than the actual temperature, then set Ac: -1, so the electronic clock is automatically reduced by 1 degree and displayed.
(Note: If you do not have a standard thermometer for reference, it is recommended to keep this as Ac: 0)
Temperature ② error calibration parameters. Positive number increases, negative number decreases, the unit is degree, the adjustment range is -5 ~ 5. For example, if you think the displayed temperature is 1 degree higher than the actual temperature, set it to AC: -1, so that the electronic clock is automatically subtracted by 1 degree and displayed again.
(Note: If you do not have a standard thermometer for reference, it is recommended to keep this as AC: 0)
3.dd
Custom cycle shows the display item
[dd: 0] for time + temperature 1 + temperature 2+ voltage
[Dd: 1] for time + temperature 1 + temperature 2
[Dd: 2] for time + temperature 1 + voltage
[Dd: 3] for time + voltage
4.Df
Switch the for time interval in custom cycle display, the unit is second, the adjustment range is 1 ~ 9. For example, dF: 3, the switching interval is about 3 seconds to switch the display item once.(Please do not set to "0")
5.LL
Display brightness level, the adjustment range is 1 ~ 3, LL: 1 is the darkest, LL: 3 is the brightest.
6.AL
Auto brightness control switch, AL: 0 to turn off the automatic brightness control, AL: 1 to turn on the automatic brightness control. When set to AL: 1, the electronic clock will change the brightness to level 1 after 19:00 everyday and change this level to level 3 every day after 07:00 am.
note:
After adjusting the AL option, press "Down" again to return to the normal display state, all parameters and for time settings can be saved.